• Outdoor Combined Power Transformer Substation
  • Outdoor Combined Power Transformer Substation

Outdoor Combined Power Transformer Substation

US$5,999.00 1 Piece (MOQ)
Port:
Shanghai, China
Production Capacity:
5000pieces/Year
Payment Terms:
L/C, T/T

New Concept Electric Inc.

Jiangsu, China

Last Login Date:

Aug 27, 2024

Business Type:

Manufacturer/Factory, Trading Company

Main Products:

Switchgear, Circuit Breaker, Recloser, Substation, Bushing, Magnetic Actuator, Vacuum Circuit Breaker

Find Similar Products

Product Description

Company Info

Basic Info.

Model NO.
YB-12/630
Rated Voltage
10/0.4kv
Rated Capacity
30-1250kVA
Rated Current
630A
Rated Frequency
50Hz
Trademark
New Concept Electric
Transport Package
Wood
Specification
1650Kg
Origin
Yangzhou
HS Code
8535210000

Product Description

Combined Power Transformer Substation

YB-12 Type outdoor box type substation, also called pre-assembled substation is a kind of distribution equipment made up of high voltage equipment, distribution transformer, low voltage distribution system and auxiliary equipment. It is installed in a moisture proof, dust proof, antirust, full sealed and removable steal type box and used under rated voltage of 10/0.4V three phase AC system as a receiver, transformer and distributor in electric system. It is very adaptable for city building and reforming, such as city public distribution system, high building, residential quarters, port, oil field, wind generating substation, enterprise, park and high speed road and so on.

YB-12 type outdoor substation has 10kV high voltage compact solid insulated switchgear, and technically has compact, small volume, environmental friendly, maintenance free, high reliability, high automation functions and so on. It is able to satisfy city electricity demands, and financially occupies small land, low invest and removable functions.

Environmental requirements:
Ambient temperature:-25ºC~40ºC
Relative humidity: daily average <95%, monthly average <90%
Wind speed: <35m/s
Altitude:<1000m
Earthquake intensity:horizontally  ≤0.4m/s2, vertically ≤0.2m/s2.
Vertical inclination::≤5°

Main technical parameter
ItemUnitValue
HV partRated voltagekV12
Rated frequencyHz50
Rated short time (1min) power frequency withstand voltage (to earth/open contacts)kV42/48
Rated lightning impulse withstand voltage (to earth/open contacts)kV75/85
Rated currentA 630
Rated short time withstand current kA20
Rated withstand current, peakkA50
LV partRated voltageV400
Main circuit rated currentA100~2500
Rated short time withstand current (to earth circuit)kA12.5
Rated withstand current, peak (to earth circuit)kV31.5
Feeder circuit currentA10~630
Feeder circuit quantityNo.1~12
Compensating capacitykVar20%~40% of transformer capacity
Transformer partRated capacitykVA30~1250
Impedance voltage%4/6
Tapping range ±2X2.5%, ±5%
Wiring connection group Dyn11, Yyn0
CabinetShell protection grade IP33D
Sound leveldBInternational Standard


 